14 Nov 2013

CBI World Group Connected To Regional Partner Hammam Industries & Co. Egypt.

- Welcome To CBI World Click Here To See Intro"
or view CBI Group Intro by clicking here'

- Visit or Email Hammam Industries & Co. Engineering Staff Egypt for Regional Supplier & Manufacturer for Original CBI Equipment & Spare Service Parts including Maintenance"

- For the latest Innovation & Technology Visit The CBI Group Today for further product design information"
Visit Hammam Industries & Co. Egypt For Regional Components & Products Maintenance Service & Spare parts provider see the range of Hammam - CBI Fans view product complete description on environmental expert for tested & certified CBI fans.
CBI Group
- Visit Masters of The Wind Web Page for Further Details" 


Email HAMMAM Supplier of CBI - CB JET Axial Fans in EGYPT & Regional Area For Tunnel Ventilation Application Inquires, Or View Installation, Use & Maintenance Manual Below or click link to download pdf. file;



View Our Related Hi Article Posts on Hi Wise Products Blog on further reading for;

1-  Click to view Post on CBI Group includes Product range & information Catalog.  

2- Click to view Post on Hi Industrial Energy Management - Fans & Blowers. Includes a information on fan optimization FAQ & a download link available to the free Fan Assessment Tool FSAT this helps quantify the potential benefits of optimizing fan system configurations that serve industrial processes.

3- Click to view Post on Hi Ventilating Giant Railway Tunnels, feature free access to The Tunneling Portal for ventilation calculations & further reading on advances on acoustics & vibration. 

Email Hammam Industries & Co Engineering Staff


6 Nov 2013

Hi Leeds Green Cooling Towers Products.

Why use recycled Water?


In today’s highly competitive markets, businesses and institutions must make wise use of available resources. Increasingly the most forward-thinking companies are partnering with local utilities to reduce their demands for energy and water, both to save costs and improve the long-term sustainability of their business.

Using highly treated recycled water for non-potable purposes is an effective way to reduce the demand for precious fresh-water resources. It is also a recognized green building practice. Recycled water has been used in industrial settings throughout California and the arid west for nearly 100 years. 

Locally, Biogen Idec, a company specializing in the development of therapeutic products for the medical field, worked with the County and City of San Diego in 2006 to convert their cooling towers to recycled water. The cooling towers at Biogen Idec are the largest users of water in the facility. 

Conversion to recycled water has allowed Biogen Idec to realize significant cost savings through discounted rates and has provided Biogen Idec with a drought-proof source of water. Elsewhere in Southern California, Orange County’s Irvine Ranch Water District provides recycled water for cooling tower and toilet-flushing use in over 40 high-rise office buildings. Los Angeles County’s West Basin Municipal Water District delivers service to the cooling towers at Cal State Dominguez Hills and the American Honda Campus. 



In Riverside County, Inland Empire Utilities Agency’s headquarters building secured 52 LEED® points to achieve Platinum Certification from the U.S. Green Building Council. Among these points was credit in the “Innovation and Design Process” category because of indoor recycled water use. There is approximately 13,000 acre-feet of recycled water reused annually within the San Diego County Water Authority (SDCWA) service area. Roughly 70% of the recycled water is used for agriculture, landscape irrigation, and other municipal and industrial uses. The annual beneficial reuse of recycled water in San Diego County is projected to increase to over 53,000 acre-feet by the year 2020. By converting to recycled water, cooling tower customers can secure a drought-proof water supply that can protect future growth potential even when water supply shortages loom. Converting to recycled water enhances overall water use efficiency and helps customers comply with their green building goals.

Operational road map to converting cooling towers




The steps for establishing an operational regime for a cooling tower are outlined below. These steps can be performed by the system owner or, as is often the practice, by its maintenance contractor.

Step 1: Determine the materials used in the cooling system and the temperature, flow rates and hours of operation. By understanding these factors, system owners can narrow the list of water quality constituents that cause concern. For example, if a system contains 304 SS, chloride levels are an important concern. However if the system is constructed of fiberglass, this water quality parameter is less of a problem.

Step 2: Evaluate the source water quality in order to understand if treatment is necessary to make the water compatible with your system materials.

Step 3: Select a treatment system if source quality is problematic. 

Step 4: Establish the desired cycles of concentration to minimize water and chemical use, without compromising system performance. While pretreatment can condition water to acceptable standards, each cycle of concentration will increase the TDS, Conductivity and Chlorine concentration in the water and at some point, these constituents will affect system performance. This point limits the cycles of concentration and establishes when blow-down should occur and make-up water added. The system manufacturer’s recommendations for conductivity and system performance with respect to TDS will likely be the limiting factors on cycles of concentration.

Step 5: Potable water back-up is necessary. This will provide increased reliability and assist with blending during conversion.

Step 6: Monitor Makeup and Blow-down water quality to confirm that the system is behaving as 
anticipated.

Step 7: Reset chemical dosing and/or cycles of concentration as necessary to achieve desired performance.

Further Reading on Cooling Tower Resources:

Click image above to Visit MESAN Group Website to View CTI certified Cooling Towers or Visit Hammam Industries & Co. your local supplier in Egypt. 

 Visit Hammam Industries & Co. Supplier of Mesan Group CTI Cooling Towers in Egypt
Click Image Above to visit Hammam Industries & Co. CTI Mesan Product Range in Egypt

The following resources provide more guidance on water best management practices.

28 Oct 2013

Hi Cooling Tower Water Efficiency.

Ways to improve water efficiency.


There are four areas where cooling tower water consumption can be reduced:

1) Evaporation:

Evaporative cooling is integral to open loop cooling towers, accounting for around 86% of cooling tower water consumption (AIRAH, 2010) and cannot be significantly reduced without degrading the cooling tower’s performance. However, locating the system in a hot and windy position will increase water waste. By reducing the heat load on the cooling tower using a dry or closed loop system, the evaporative cooling work can be reduced.

2) Blow-down

Blow-down water is a vital process to preserve long life and efficiency of equipment as it reduces the build up of solids (salts, dirt, calcium, rust) in the system. The frequency of blow-down discharge is typically monitored by measuring cooling water conductivity. Water consumption can be reduced by:

• Improving the quality of feed water
• Optimizing the cooling tower process, and
• Removing solids from blow-down water before

Recirculating this water into the system. It is possible to reduce blow-down volume without compromising plant longevity and efficiency by automating blow-down based on the conductivity of the circulating water to maintain the maximum allowable solids/conductivity (while staying within system requirements).

3) Reuse of Blow-down

A growing number of companies are now collecting blow-down water for reuse onsite instead of using
potable water. Blow-down water is typically higher in dissolved solids but can be (provided there are no harmful chemical treatments or risks of biological contamination) used for:

• wash down
• cleaning, and
• toilet flushing.

Depending on the types of plants and grasses in the gardens blow-down water can be used to offset or replace irrigation water. [It is wise to test this water on a small section of the gardens to see if there are any negative effects.] Blow-down can also be deionised and reused in the cooling circuit [provided there is chemical compatibility].

4) Drift, Splash-out, overflow and other losses

Cooling tower efficiency can be improved by locating the tower in areas not exposed to high winds or excessive heat. Winds can cause spray drift and splash out from air inlets. Design features such as drift eliminators or internal walls will reduce water loss in open loop cooling towers. In some cases, drift from the cooling towers may pose a public health issue. Overflow can happen when a poorly adjusted float valve (or bad design) lets the tower overfill until water flows straight out the overflow and into the sewer. This problem can be avoided by checking during routine maintenance and by monitoring water consumption. Overflow water can also be diverted to storage for reintroduction either with or without processing for use in the make-up water. Make-up water is the water added to compensate for all the water losses through the system. The more efficient the system the less make up water required. Leaks can be detected either by inspection, performing a mass balance or direct metering of flows. Leaks, however small in appearance, can be significant, in some cases 30% of a company’s water usage.


Checklist of Water Efficiency Improvements


1 - Calculate cooling tower water efficiency using the cooling tower water efficiency calculator.
2 - Determine a baseline and compare with industry benchmarks. This will also help assess the success of each water saving action.
3 - Ensure make up water valves and overflow valves are correctly set.
4 - Eliminate all leaks and monitor consumption.
5 - Check if make-up water can be replaced with recycled, rain or storm water feeds.
6 - Improve plant design, location and environment to optimize efficiency.
7 - Pre-cool water with a dry heat ex-changer to reduce heat load on cooling tower (hybrid systems).
8 - Improve plant design to eliminate overflow, splash-out, and drift.
9 - Continuously monitor blow-down water to maintain a higher average conductivity, thus reducing total blow-down.
10 - Investigate and implement recycling blow-down for reuse.

*References: AIRAH, Dec 2010, Cooling system water efficiency study project report.

Hi Blog List.

Hi Translate.

Hi Smoke Poll, User Star Rating!.

Hammam Industries & Co.

Hammam Industries & Co.
'Regional MESAN CTI Certified Cooling Towers Suppliers'

The Hi European Commission.

The Hi European Commission.
"The Latest EU Industry Regulations Information".

Hi Wikipedia Search.

Search results

Hi Blogger Contact Form.

Name

Email *

Message *

Hi Revenue Slider